ภาษาไทย  Eng
A A A
MAX BRIGHT » Central Units > CU-M Series


 







CU-M Series 12V
(
Output 12 VDC)

MODEL LOAD DC
BATTERY DURATION
(Hrs.) _+10%
DIMENSION  
W x L x H (cm)
CU 15-12- M 70 Watt 12V. 15Ah. 2 37 x 9 x 26
CU 18-12- M 85 Wattt 12V. 18Ah.
CU 21-12- M 100 Watt 12V. 21Ah.
CU 23-12- M 110 Watt 12V. 24Ah.
CU 26-12- M 120 Watt 12V. 26Ah.
CU 35-12- M 160 Watt 12V. 35Ah. 34 x 16.5 x 26
CU 40-12- M 180 Watt 12V. 40Ah.

CU-M Series 24V
(Output 24 VDC)
MODEL LOAD DC BATTERY DURATION
(Hrs.) _+10%
DIMENSION  
W x L x H (cm)
CU 07-24- M 70 Watt 24V. 7.2Ah. 2 37 x 18 x 26
CU 12-24- M 110 Watt 24V. 12Ah.
CU 15-24- M 140 Watt 24V. 15Ah.
CU 18-24- M 200 Watt 24V. 21Ah.
CU 21-24- M 220 Watt 24V. 24Ah.
CU 26-24- M 250 Watt 24V. 26Ah.
Specification
 Mode  of  Operation :   Non - Maintained
 Lamp :   Tungsten  Halogen  or  Dichroic 
    Halogen,  with  180º adjustable  sets 
    and
plastic-cover  anti-dust
 Main  Supply :   AC  220 Volt, 50 Hz, 10%  Single  Phase
 Control System :   8  bit  Micro  Controller  Unit  (MCU)  with
   
solid state  automatic battery charger  full 
    function low / high  charge  and 
    discharge, low / high voltagecut - off
    
preventing  battery  defects
Construction :   Electro-Galvanized  steel  sheet 1 mm.
   
with  epoxy  powder and stove  enamel
    coated  anti-rust  corrosion  proof  or
    ABS  Flame Retardant  UL 94 V - O
Battery :   Sealed  lead  acid  battery, based  o
    ISO  9001,  ISO 14001  certified  and  UL
 Charging  Period :   15-20  Hours  as  required
 Manual Test :   Push  Button  and  Infrared  Remote
   
Control as  below  features :

Function  Test Status L.E.D.
Normal 5  seconds  discharge - -
Monthly 30  minutes  discharge Red
Half  Year 60  minutes  discharge
Fail  to  Test Flashing
Automatic  Test       :   Real  time  clock - setting  with  8  bit  MCU
Function  Test Exercise  Status - Selectable
1  Week 30, 60, 90  and  120/180  minutes
2, 4, 6, 8  Weeks
12  Week
24  Week

Safety  Features :     Low - High  voltage  cut-off, preventing
        
battery  over discharge and  recharge
      AC  fuse - preventing  short  circuit  and
       
overload  for  main incoming  AC  220 Volt
      DC  fuse - preventing  short  circuit  and
       
overload  for charging & load
Accessories :     On / Off  switch  for  lamps  
      LED.  AC  indicates  main  incoming  AC
       
220 Volt
      LED.  FULL  indicates  charging, and  fully 
       
charged
      LED.  FAIL  indicates  fail  to  charge
      LED.  AUTO - TEST  indicates  fully
       
automatic functional
      LED.  IR  indicates  infrared  remote  test
       
functional
      Time  Delay  1  up  to  10  minutes

 

Emergency  lighting  indicators

1.  AC                                        :  Main  incoming  AC  220 Volt
2.  FULL                                   :  Charge, and  fully  charged
3.  FAIL                                     :  Fail  to  charge
4.  AUTO  TEST                      :  Fully  automatic  functional
5.  IR                                         :  Infrared  remote  test
                                                     functional
6.  BACK  TIME  (Minutes)    :  Record  latest  duration  time
7.  IR  RECEIVER                  :  Infrared  receiver  signal  port
8.  60  minutes  Test             :  Half  year  push  button
                                                    
status
9.  30  minutes  Test             :  Monthly  push  button  status
10.  Fail  (TEST  SYSTEM)   :  Fail  to  test  half  year  and
                                                     monthly  status
11.  Normal  Test                  :  Test  battery  5  seconds
                                                     discharge 
12.  Monthly  Test                  :  Test  battery  30  minutes
                                                     discharge 
13.  Half  Year  Test              :  Test  battery  60  minutes
                                                     discharge 
14.  On / Off  switch               :  Switch  on / off  for  lamps
15.  AC  FUSE                        :  Preventing  short  circuit  and
                                                     overload  for  main  incoming
                                                     AC  220 Volt